What is aluminum pigtailing?

Pigtailing means splicing a short length of copper wire onto each aluminum conductor, then connecting the copper, not the aluminum, to the outlet, switch or fixture. The splice between copper and aluminum is made with a connector designed for that job.

It is the most common way to repair aluminum branch wiring without rewiring the whole building.

Why does aluminum wiring need to be repaired?

Aluminum expands and contracts more than copper as it heats and cools, and it forms an oxide layer that resists current. Over the years, connections at devices work loose and run hot. The U.S. Consumer Product Safety Commission reports that homes wired with pre-1972 aluminum branch circuit wire are 55 times more likely to have one or more connections reach fire hazard conditions than homes wired with copper. The CPSC describes the wiring in homes built from about 1965 to the mid-1970s.

Which connectors make pigtailing work?

The connector matters more than the wire. The CPSC accepts two repair connectors, and we install both:

Ordinary twist-on wire nuts are not an approved fix, and the CPSC does not recommend them. Replacing outlets with CO/ALR-rated devices only addresses the connection at the device, and the CPSC does not recommend relying on them alone.

What does a pigtailing job include?

  1. Inspect the panel, outlets, switches and fixtures and confirm the wiring is aluminum
  2. Shut off the circuits and verify they are dead
  3. Cut back to clean conductor and prepare the aluminum
  4. Join a copper pigtail to each aluminum conductor with an approved connector
  5. Connect the copper to the device, tighten to specification and test
  6. Close up, restore power and check the circuit

How many connections are there?

Every outlet, switch and light fixture on an aluminum circuit is a connection point, so even a small home has dozens. Apartments and commercial buildings can have many more. We do aluminum wiring work in homes, apartment communities and commercial buildings, and we plan larger jobs by unit or by floor.

How do you know if you have aluminum wiring?

Check the cable jacket where it enters the panel or in an attic. Aluminum cable is usually marked AL or ALUMINUM. Homes built in Phoenix from the mid-1960s to the mid-1970s are the ones to check first. If you cannot tell, we can identify it during a visit. Our aluminum wire and repair page covers all repair options.

Arizona ROC #153656 (CR-11) | Over 40 years in business

OUR PROCESS

HOW DOES A JOB WITH PHOENIX CONTRACTING SERVICES WORK?

Every job follows three steps: a site walkthrough, testing and documentation, then findings and next steps.

01

WALKTHROUGH AND SCOPE

We start with a free phone consultation, and you can send a photo of your panel or equipment. If on-site work is needed, we visit, look at the panels and service, and agree on what needs to be tested or repaired before any work starts. On-site work is quoted before it begins.

02

TESTING AND DOCUMENTATION

Load loggers and a thermal camera record what the equipment is doing, and the results are documented for each panel or component we check.

03

FINDINGS AND NEXT STEPS

We go over what we found and your options in plain language. If corrective work is needed, we are licensed to do it.

WHAT CUSTOMERS SAY ABOUT US

5.0 VERIFIED GOOGLE RATING
It actually started in Fall 2020 with my Garage losing power. I bid out the work and hired Phoenix Contracting Services. The following Monday, Jeff and his crew (Mike and Gabriel) came out and finally resolved the issue See more
Jeff’s knowledge, experience and professionalism are exemplary! We contracted him to provide engineering plans to permit our relocation and upgrade of electrical service meter. He worked with my electricians on details See more
We woke to a Friday morning with weird lighting fluctuations. I checked the service panel to find a burning smell and melted bus bar under AC breaker. Since bus bar was melted, I contacted SRP who provided some certified See more

Is pigtailing a permanent fix?
It holds up as long as the connector is installed correctly. AlumiConn is accepted by the CPSC, and it relies on set screws that are tightened to specification.
Can I just replace the outlets with CO/ALR outlets?
That only addresses the connection at the device. The CPSC does not recommend relying on CO/ALR devices alone.
Do I have to rewire the whole house instead?
Rewiring with copper is the most complete fix, but it is also the most invasive and costly. Pigtailing with an approved connector is the accepted alternative.
How long does a pigtailing job take?
It depends on the number of connection points. A small home can be done in a day or two. Apartment and commercial jobs are planned by unit or floor.
Does aluminum pigtailing need a permit?
That varies by city. We tell you at the quote stage if your city requires one.

Tell Us What Your Electrical System Needs

Share the details of your project, and our team will help you identify the most practical next step.